NEETAceToday's NEET Daily

Wattless current, AC generator and transformer: NEET MCQs with answers

147 questions on this topic of Electromagnetic Induction and Alternating Currents for NEET 2027, using the verified 2026 syllabus baseline. Here are 12; tap one to see its answer and explanation.

Practise Electromagnetic Induction and Alternating Currents freeAll Electromagnetic Induction and Alternating Currents questions

Free with a Google sign-in; NEET Daily needs no sign-in at all.

easyNEET 2024

1. In an ideal transformer, the turns ratio is Np/Ns = 1/2. The ratio Vs : Vp is equal to (the symbols carry their usual meaning):

  1. 1 : 4
  2. 1 : 2
  3. 2 : 1
  4. 1 : 1
Show answer and explanation

Answer: (C) 2 : 1

For an ideal transformer Vs/Vp = Ns/Np = 2/1, so Vs : Vp = 2 : 1 (a step-up transformer).

NCERT Class 12

easy

2. An ideal transformer has 100 turns in the primary and 1000 in the secondary. The secondary delivers 0.5 A. The primary current is:

  1. 500 A
  2. 5 A
  3. 0.5 A
  4. 0.05 A
Show answer and explanation

Answer: (B) 5 A

For an ideal transformer V_pI_p = V_sI_s and V_s/V_p = N_s/N_p, so I_p = I_s N_s/N_p = 0.5 × 1000/100 = 5 A.

NCERT Class 12

medium

3. For Alternating Current, assess the following statements. Match List I with List II: pair each incorrect statement with its corrected version. List I A. A step-up transformer has fewer turns in its secondary than its primary. B. An ideal transformer creates extra output power whenever its voltage is increased. C. An ideal step-up transformer increases voltage and current simultaneously without changing input power. D. A transformer gives sustained secondary emf from an unchanging primary direct current after all transients end. List II I. An ideal step-up transformer reduces current at the corresponding load power. II. A step-up transformer has more turns in its secondary than its primary. III. A transformer requires a changing magnetic flux for sustained induction. IV. For an ideal transformer, input and output powers are equal. Choose the correct answer from the options given below:

  1. A-II, B-I, C-IV, D-III
  2. A-III, B-II, C-I, D-IV
  3. A-II, B-IV, C-I, D-III
  4. A-II, B-IV, C-III, D-I
Show answer and explanation

Answer: (C) A-II, B-IV, C-I, D-III

The correct relationships are: A step-up transformer has more turns in its secondary than its primary. For an ideal transformer, input and output powers are equal. An ideal step-up transformer reduces current at the corresponding load power. A transformer requires a changing magnetic flux for sustained induction.

NCERT Class 12

hard

4. A step-up transformer operates on a 220 V line and delivers a current of 2 A to an external load at 2200 V. If the primary winding has a resistance of 0.3 Ω and the secondary winding has a resistance of 15 Ω, what is the total copper loss in the windings?

  1. 120 W
  2. 180 W
  3. 60 W
  4. 240 W
Show answer and explanation

Answer: (B) 180 W

Assuming negligible power loss for turns ratio calculation, V_s / V_p = 2200 / 220 = 10. Thus, primary current is I_p ≈ I_s × 10 = 2 × 10 = 20 A. Copper loss in primary = (I_p)² R_p = (20)² × 0.3 = 400 × 0.3 = 120 W. Copper loss in secondary = (I_s)² R_s = (2)² × 15 = 4 × 15 = 60 W. Total copper loss = 120 W + 60 W = 180 W.

NCERT Class 12

medium

5. Given below are two statements: Statement I: A transformer works on mutual induction and can step up a steady DC voltage. Statement II: The average power drawn by an ideal inductor in an AC circuit is zero. In the light of the above statements, choose the most appropriate answer from the options given below:

  1. Both Statement I and Statement II are true
  2. Both Statement I and Statement II are false
  3. Statement I is true but Statement II is false
  4. Statement I is false but Statement II is true
Show answer and explanation

Answer: (D) Statement I is false but Statement II is true

A transformer needs a changing flux, so a steady DC gives no induced emf in the secondary: Statement I is false. In a pure inductor current lags voltage by π/2, so the power factor cos 90° = 0 and the average power is zero: Statement II is true.

NCERT Class 12

easy

6. A 24 V, 24 W lamp is connected to the secondary of a step-down transformer whose primary is connected to 240 V ac mains. Assuming the transformer to be ideal, the current in the primary winding is:

  1. 0.2 A
  2. 0.1 A
  3. 1 A
  4. 0.01 A
Show answer and explanation

Answer: (B) 0.1 A

In an ideal transformer the input power equals the output power, 24 W. So I_p = P/V_p = 24/240 = 0.1 A (the lamp itself draws 1 A at 24 V). Same type as NEET 2023, Q4.

NCERT Class 12

hard

7. A step-down transformer has an efficiency of 85%. It reduces 2200 V to 220 V to operate a device having an impedance of 22 Ω. Assuming a purely resistive load, the current drawn by the primary coil from the mains is:

  1. 10.0 A
  2. 0.85 A
  3. 1.00 A
  4. 1.18 A
Show answer and explanation

Answer: (D) 1.18 A

Secondary voltage V_s = 220 V and R = 22 Ω, so secondary current I_s = 220 / 22 = 10 A. Output power P_out = V_s × I_s = 220 × 10 = 2200 W. With efficiency η = 0.85, input power P_in = P_out / η = 2200 / 0.85 ≈ 2588.2 W. Since P_in = V_p × I_p, the primary current is I_p = 2588.2 / 2200 = 1 / 0.85 ≈ 1.18 A.

NCERT Class 12

easy

8. A 24 V, 60 W lamp is connected to the secondary of a step-down transformer whose primary is connected to 220 V ac mains. Assuming the transformer to be ideal, the current in the primary winding is:

  1. 0.273 A
  2. 0.109 A
  3. 2.73 A
  4. 2.5 A
Show answer and explanation

Answer: (A) 0.273 A

In an ideal transformer the input power equals the output power, 60 W. So I_p = P/V_p = 60/220 = 0.273 A (the lamp itself draws 2.5 A at 24 V). Same type as NEET 2023, Q4.

NCERT Class 12

easy

9. A 12 V, 60 W lamp is run from the secondary of an ideal step-down transformer connected to a 240 V AC supply. The current drawn from the 240 V supply is:

  1. 0.50 A
  2. 5.0 A
  3. 0.25 A
  4. 2.5 A
Show answer and explanation

Answer: (C) 0.25 A

For an ideal transformer, input power equals output power: P_in = P_out = 60 W. Therefore, V_p × I_p = 60 W, which gives I_p = 60 / 240 = 0.25 A.

NCERT Class 12

easy

10. A 12 V, 100 W lamp is connected to the secondary of a step-down transformer whose primary is connected to 240 V ac mains. Assuming the transformer to be ideal, the current in the primary winding is:

  1. 8.33 A
  2. 0.05 A
  3. 4.17 A
  4. 0.417 A
Show answer and explanation

Answer: (D) 0.417 A

In an ideal transformer the input power equals the output power, 100 W. So I_p = P/V_p = 100/240 = 0.417 A (the lamp itself draws 8.33 A at 12 V). Same type as NEET 2023, Q4.

NCERT Class 12

easy

11. A 6 V, 60 W lamp is connected to the secondary of a step-down transformer whose primary is connected to 230 V ac mains. Assuming the transformer to be ideal, the current in the primary winding is:

  1. 2.61 A
  2. 0.0261 A
  3. 10 A
  4. 0.261 A
Show answer and explanation

Answer: (D) 0.261 A

In an ideal transformer the input power equals the output power, 60 W. So I_p = P/V_p = 60/230 = 0.261 A (the lamp itself draws 10 A at 6 V). Same type as NEET 2023, Q4.

NCERT Class 12

easy

12. An ideal transformer has 200 turns in the primary and 25 in the secondary. The secondary delivers 0.5 A. The primary current is:

  1. 0.0625 A
  2. 0.5 A
  3. 4 A
  4. 12.5 A
Show answer and explanation

Answer: (A) 0.0625 A

For an ideal transformer V_pI_p = V_sI_s and V_s/V_p = N_s/N_p, so I_p = I_s N_s/N_p = 0.5 × 25/200 = 0.0625 A.

NCERT Class 12

Keep going with Electromagnetic Induction and Alternating Currents. All 806 questions with instant answers, your mistakes saved for revision and your accuracy by topic.

Other topics in Electromagnetic Induction and Alternating Currents